Section 45-24.3-8 Minimum standards for light and ventilation.

RI Gen L § 45-24.3-8 (2019) (N/A)
Copy with citation
Copy as parenthetical citation

§ 45-24.3-8. Minimum standards for light and ventilation. (a) No person shall occupy as owner or occupant, or let to another for occupancy, any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the requirements of this section.

(b) Every habitable room must have at least one window or skylight facing directly outdoors (provided that if connected to a room or area used seasonally (e.g., porch) then adequate daylight must be possible through this interconnection). The minimum total window area, measured between stops, for every habitable room is not less than ten percent (10%) of the floor area of that room. Whenever walls, or other portions of structures, face a window of the room, and light obstructing structures are located less than three feet (3') from the window and extend to a level above that of the ceiling of the room, the window is not deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight type window in the top of the room, the total window area of the skylight shall equal at least ten percent (10%) of the total floor area of the room. Each window is not less than three (3) square feet in area.

(c) Every habitable room must have at least one window or skylight facing directly outdoors which can be easily opened, or other device to adequately ventilate the room; provided, that if connected to a room or area used seasonally, then adequate ventilation must be possible through this interconnection. The total of openable window area in every habitable room must be equal to at least fifty percent (50%) of the minimum window area size, or minimum skylight type window size, as required in this section, except where there is supplied some other device affording adequate ventilation and lighting approved by the appropriate authority.

(d) Every bathroom and water closet compartment and nonhabitable room used for food preparation must comply with the light and ventilation requirements for habitable rooms contained in this section, except that no window or skylight is required in adequately ventilated bathrooms and water closet compartments equipped with a ventilation system approved by appropriate authority.

(e) Where there is usable electric service available from power lines, not more than three hundred feet (300') away from a dwelling, every dwelling unit, and all public and common areas, must be supplied with electric service, outlets and fixtures which are properly installed, maintained in good and safe working condition, and connected to the source of electric power in a manner prescribed by the ordinances, rules, and regulations of the corporate unit. The minimum capacity of these services, and the minimum number of outlets and fixtures, are as follows:

(1) Every habitable room must have electric service and outlets and/or fixtures capable of providing at least three (3) watts per square foot of floor area.

(2) Every habitable room and nonhabitable room used for food preparation must have at least one floor or wall type electric convenience outlet for each sixty (60) square feet, or fraction thereof, of floor area, and in no case less than two (2) outlets.

(3) Every water closet compartment, bathroom, and kitchen or kitchenette, laundry room, furnace room, and public hall must contain at least one supplied ceiling, or wall, electric light fixture.

(4) Convenient switches or equivalent devices for turning on one light in each room or passageway must be located so as to permit the area ahead to be lighted.

(5) Every public hall and stairway in every multiple dwelling must be adequately lighted by natural or electric light at all times to provide in all parts at least six (6) footcandles of light at the tread or floor level. Every public hall and stairway, in structures containing not more than three (3) dwelling units, may be supplied with conveniently located light switches, controlling an adequate lighting system which may be turned on when needed, instead of full time lighting.

History of Section. (P.L. 1970, ch. 325, § 1; P.L. 1972, ch. 118, § 3.)

LegalFix

Copyright ©2024 LegalFix. All rights reserved. LegalFix is not a law firm, is not licensed to practice law, and does not provide legal advice, services, or representation. The information on this website is an overview of the legal plans you can purchase—or that may be provided by your employer as an employee benefit or by your credit union or other membership group as a membership benefit.

LegalFix provides its members with easy access to affordable legal services through a network of independent law firms. LegalFix, its corporate entity, and its officers, directors, employees, agents, and contractors do not provide legal advice, services, or representation—directly or indirectly.

The articles and information on the site are not legal advice and should not be relied upon—they are for information purposes only. You should become a LegalFix member to get legal services from one of our network law firms.

You should not disclose confidential or potentially incriminating information to LegalFix—you should only communicate such information to your network law firm.

The benefits and legal services described in the LegalFix legal plans are not always available in all states or with all plans. See the legal plan Benefit Overview and the more comprehensive legal plan contract during checkout for coverage details in your state.

Use of this website, the purchase of legal plans, and access to the LegalFix networks of law firms are subject to the LegalFix Terms of Service and Privacy Policy.

We have updated our Terms of Service, Privacy Policy, and Disclosures. By continuing to browse this site, you agree to our Terms of Service, Privacy Policy, and Disclosures.
Section 45-24.3-8 Minimum standards for light and ventilation.