LegalFix

Section 39 - Inspection Tests; Preparation

MA Gen L ch 146 § 39 (2019) (N/A)
Copy with citation
Copy as parenthetical citation

Section 39. The air tank or other receptacle shall be prepared for internal inspection by the owner or user. The inspection plugs, handhole plates and manhole plates if provided shall be removed. The interior shall be cleaned of rust, scale, oil sludge and any other deleterious material. Ultrasonic thickness determination shall be permitted in lieu of, or in conjunction with, internal inspection for air tanks or other receptacles of 36 inches diameter or less. Thickness measurements shall be made in at least 8 areas: 2 on each head and 2 on both the top and bottom portions of the shell. Thickness determinations indicating significant reduction in material thickness over a general area shall be shown on the inspection report, as well as calculations for the reduction in allowable working pressure. The authorized inspector's employer shall be responsible for the inspector's or the ultrasonic examiner's competency in the use of the ultrasonic thickness gauge and the examiner's signed report shall be attached to the authorized inspector's inspection report. A hydrostatic test shall be applied if required by the authorized inspector. The pressure applied during the test shall be equal to one and one half times the pressure allowed on the air tank or other receptacle. A hammer test may also be applied if there is no pressure on the tank or receptacle.

LegalFix

Copyright ©2024 LegalFix. All rights reserved. LegalFix is not a law firm, is not licensed to practice law, and does not provide legal advice, services, or representation. The information on this website is an overview of the legal plans you can purchase—or that may be provided by your employer as an employee benefit or by your credit union or other membership group as a membership benefit.

LegalFix provides its members with easy access to affordable legal services through a network of independent law firms. LegalFix, its corporate entity, and its officers, directors, employees, agents, and contractors do not provide legal advice, services, or representation—directly or indirectly.

The articles and information on the site are not legal advice and should not be relied upon—they are for information purposes only. You should become a LegalFix member to get legal services from one of our network law firms.

You should not disclose confidential or potentially incriminating information to LegalFix—you should only communicate such information to your network law firm.

The benefits and legal services described in the LegalFix legal plans are not always available in all states or with all plans. See the legal plan Benefit Overview and the more comprehensive legal plan contract during checkout for coverage details in your state.

Use of this website, the purchase of legal plans, and access to the LegalFix networks of law firms are subject to the LegalFix Terms of Service and Privacy Policy.

We have updated our Terms of Service, Privacy Policy, and Disclosures. By continuing to browse this site, you agree to our Terms of Service, Privacy Policy, and Disclosures.
Section 39 - Inspection Tests; Preparation