LegalFix

Section 25-9-277 - Handling and use of explosives and detonators.

AL Code § 25-9-277 (2019) (N/A)
Copy with citation
Copy as parenthetical citation

(a) Only designated persons shall cut, cap, and issue capped fuses and explosives.

(b) When cutting fuse, it shall be cut square across with a sharp clean instrument and the cap crimper used shall be of a type recommended by explosive manufacturers. A bench type crimper is recommended.

(c) No explosives container shall be opened with any metallic instrument.

(d) No person shall remove any explosives from a pit magazine without permission of the pit superintendent, foreman, or a person designated by the operator.

(e) Capped fuse or electric detonators shall not be stored within 50 feet of other explosives, power lines, cables, or other electrical conductors.

(f) Oils or other combustible substances shall not be stored within 50 feet of any explosives.

(g) Detonators shall not be removed from containers except as they are used for capping fuses or, in the case of electric detonators, as they are used in preparing primers, except when placed in other containers as recommended by manufacturers.

(h) Fuse shall not be cut and capped nearer than 50 feet to any explosives magazine.

(i) Paper, sawdust, wooden boxes, or cartons shall be placed at a safe distance from any magazine, and each day's accumulation shall be removed at the end of the shift.

(j) Fuse shall be cut long enough to extend beyond the collar of a loaded drill hole, and in no case shall it be less than four feet in length.

(k) Small supplies of explosives or detonators stored in a pit shall be stored in magazines constructed in accordance with the specifications set forth in Section 25-9-131. In no case shall more than 200 pounds of explosives be stored at one time in such magazine.

(l) Magazines located in the pit should not be nearer than those standards set forth in the American Table of Distances for Storage of Explosives, a publication of the Institute of Makers of Explosives.

(m) No fuse shall be used that burns faster than one foot in 30 seconds or slower than one foot in 55 seconds according to the manufacturer's rating.

(n) In capping fuse, at least one inch shall be cut from the end of each coil or roll of fuse used.

LegalFix

Copyright ©2024 LegalFix. All rights reserved. LegalFix is not a law firm, is not licensed to practice law, and does not provide legal advice, services, or representation. The information on this website is an overview of the legal plans you can purchase—or that may be provided by your employer as an employee benefit or by your credit union or other membership group as a membership benefit.

LegalFix provides its members with easy access to affordable legal services through a network of independent law firms. LegalFix, its corporate entity, and its officers, directors, employees, agents, and contractors do not provide legal advice, services, or representation—directly or indirectly.

The articles and information on the site are not legal advice and should not be relied upon—they are for information purposes only. You should become a LegalFix member to get legal services from one of our network law firms.

You should not disclose confidential or potentially incriminating information to LegalFix—you should only communicate such information to your network law firm.

The benefits and legal services described in the LegalFix legal plans are not always available in all states or with all plans. See the legal plan Benefit Overview and the more comprehensive legal plan contract during checkout for coverage details in your state.

Use of this website, the purchase of legal plans, and access to the LegalFix networks of law firms are subject to the LegalFix Terms of Service and Privacy Policy.

We have updated our Terms of Service, Privacy Policy, and Disclosures. By continuing to browse this site, you agree to our Terms of Service, Privacy Policy, and Disclosures.
Section 25-9-277 - Handling and use of explosives and detonators.